Use of a pipettor for blood collection from the inner canthus of mice
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Objective To explore the practical value of a modified method for blood collection from the inner canthus of mice using a pipettor. Methods A total of 20 male C56BL/6J mice were divided into two groups, the pipettor group and the capillary group (10 mice in each group). Blood samples were taken 3 times from the inner canthus of the mice with a pipettor or glass capillary, respectively, and the time-consumption and success rate of the two groups were recorded and compared. Results The success rates of both the blood collection methods were 100%. However, in the pipettor group, the blood collection was completed faster than the capillary group with a significant difference (P < 0.05). Conclusions It is a relatively simple and safe method for blood collection from the inner canthus of mice using a pipettor.