    摘要:

    目的 利用流感病毒作为模式病毒评价非人灵长类动物口鼻式气溶胶暴露系统的运行效果,为非人灵长类动物气溶胶吸入研究奠定实验基础。 方法 在生物安全三级实验室中,使用非人灵长类动物口鼻式气溶胶暴露系统产生流感病毒气溶胶,以此评价该装置能否正常运行并产生特定粒径大小的气溶胶颗粒,同时评价装置运行过程中病毒气溶胶输出均一性、稳定性、气密性以及装置的消毒效果。 结果 该装置产生的气溶胶颗粒中值直径为(1. 04±0. 03)μm,不同浓度气溶胶发生液产生的病毒气溶胶均能到达头罩,且 6 个头罩间气溶胶浓度无显著性差异(P>0. 05);流感病毒雾化 30 min 后存活率>50%;病毒气溶胶浓度与发生器病毒浓度的线性相关良好 (R2 = 0. 9989);装置易泄漏处未检测到感染性病毒,使用过氧化氢消毒剂对气溶胶暴露系统管道及负压柜腔体消毒后无指示菌生长。 结论 非人灵长类动物口鼻式气溶胶暴露系统运行效果良好,装置管道气密性好,可消毒完全,为将来建立 SARS-CoV-2 及其它病毒气溶胶感染非人灵长类动物模型奠定了基础。

    Abstract:

    Objective To evaluate the operation of an oral and nasal aerosol exposure system for non-human primate (NHP) models using influenza virus and establish the experimental basis for aerosol inoculation of NHPs with SARS-CoV-2. Methods In a biosafety level 3 laboratory, we generated influenza virus B/ Phuket / 3073 / 2013 aerosol using an oral and nasal aerosol exposure system for NHP models and evaluated whether the device could run normally and produce aerosol particles of a specific size. Furthermore, the uniformity of distribution and stability of the aerosol particles were analyzed. Influenza virus was collected at sites where leakage could easily occur. A solution of 35% H2O2 was run through the nebulizer to disinfect the system. Results The mass median aerodynamic diameter of aerosol particles was (1. 04 ± 0. 03) μm. The viral aerosols produced by different concentrations of influenza virus reached the hood. There was no significant difference in aerosol concentration among the 6 hoods (P>0. 05). The survival rate of influenza virus was greater than 50% after atomization for 30 min. A linear relationship was observed ( R2 = 0. 9989) with an average difference of 2. 4 log10 CCID50 / mL between input (Collison Nebulizer) and output (All Glass Impinger-30) virus titers. No influenza virus was detected at potential leakage sites of the device. There was no indication of bacterial growth after sterilizing the pipeline of the aerosol exposure system and the cavity of the negative pressure cabinet with hydrogen peroxide disinfectant. Conclusions Our result suggest that the oral and nasal aerosol exposure system for non-human primates is useable and effective. This study provides a foundation for establishing SARS-CoV-2 and other viral aerosol infection models using NHPs in the future.

    参考文献
    相似文献
    引证文献
引用本文

李庆妮,陈云丰,刘元浪,唐 定,华婉璐,张瑞安,卢 佳,李新国.非人灵长类动物口鼻式气溶胶暴露系统运行效果评价[J].中国比较医学杂志,2022,32(6):80~86.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2021-08-06
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2022-08-01
  • 出版日期:
自2024年1期开始,杂志参考文献改为中英文对照,具体格式要求可置下载中心查看!
关闭